18柱(200 mm×4.6 mm,5 μm),流動相為醋酸銨緩沖溶液(pH 6.0)-乙腈-甲醇(80∶15∶5),檢測波長為280 nm,體積流量為1.0 mL/min,柱溫為25℃,進樣量為20 μL。結果 米諾環(huán)素在0.05~1 mg/mL線性關系良好(r=0.999 7),方法精密度RSD為0.6%,平均回收率為99.46%,RSD為0.8%,各雜質峰與主峰分離良好。結論 該方法簡便,專屬性強,準確可靠,可用于測定鹽酸米諾環(huán)素緩釋微丸膠囊中的米諾環(huán)素及有關物質。;Objective To establish an HPLC method for the determination of minocycline hydrochloride and its related substances in minocycline hydrochloride sustained-release pellets capsules. Methods HPLC was performed on a Diamonsil C18 column (200 mm × 4.6 mm, 5 μm) using ammonium acetate (pH 6.0)-acetonitrile-methanol (80:15:5) as the mobile phase at a flow rate of 1.0 mL/min. The detection wavelength was 280 nm and the column temperature was 25 ℃. Results The linear range of minocycline was 0.05—1 mg/mL (r = 0.999 7), precision RSD = 0.6%, and the average recovery was 99.46% (RSD = 0.8%). Conclusion The established method is simple, accurate, and specific, and could be used for the quality control of minocycline hydrochloride sustained-release pellets capsules."/>